3. Hold a piece of paper at the lens surface, adjust offsets as necessary until the image is centered
within the lens perimeter. A full white field works best for this.
4. If necessary, center the image on the screen. If the projector is mounted off-center to the
screen axis, then offset the lens as much as required. Aim the projector over slightly towards
the center of the screen, but use caution, as too much tilt will cause excessive keystone
distortion. Lens offset will not.
5. With the test pattern on screen, double-check projector leveling so the top edge of the image is
parallel to the top edge of the screen. Make sure the projector is positioned in the throw
distance range for the lens in use.
Folded Optics
In rear screen applications where space behind the projector is limited, a mirror may be used to
fold the optical path. The position of the projector and mirror must be accurately set—if considering
this type of installation contact Christie Customer Support for assistance.
Boresight Alignment
1. Display the Boresight test pattern by
pressing Test on the IR remote and use the
Left arrow key to cycle to Boresight.
2. Adjust the lens focusing ring until each
square displayed in the Boresight test
pattern is focused. If all three squares are
in focus, no further action is required.
3. If boresight is required, see the image on
the right to understand how the adjustment
screws on the lens mount affect the
corresponding squares on the test pattern.
4. Use a 5 mm hex key to loosen the three
locking set screws on the lens mount. The
set screws must be backed out several
turns, so that they do not contact the inner
lens mount plate.
5. Fine tune the focus of square one, by
adjusting the appropriate cap screw. Adjust until the image is in focus with minimal flare.
6. Adjust square 2, by adjusting the appropriate cap screw. Adjust until the image is in focus with
minimal flare.
• Boresight alignment is an advanced feature and should only be performed by experienced
users.
• You can also use the Grid or Edge blend test pattern to perform boresight alignment.