SLC Series Xenon Console
4-4 CHRISTIE INCORPORATED
February, 1999
4.2.2. DOOR PANELS
All three door panels are removable for easier access to the interior of the console during
installation and maintenance.
To remove door panel:
1. Unlock key-lock.
2. Open door.
3. Push down on spring-loaded pin hinge.
4. Remove panel.
To install door panel, reverse the above procedure.
4.2.3. VENTING
It is necessary to vent hot exhaust air from console to the outside of the building.
1. Connect a eight-inch inner-diameter, flexible, fireproof ducting material to exhaust duct
(Item 1 in Figure A-2) on top of lamphouse.
2. Ensure that there are no obstructions in ducting, and that air intake openings of console
are unobstructed.
If ozone-free lamps are used, a short, vertical exhaust stack may be used, provided local
codes do not require the exhaust to be vented directly outside.
Minimum and maximum exhaust airflow requirements for all SLC series models are shown
in Figure 4-3.
Model Minimum Exhaust (ft
3
/min) Maximum Exhaust (ft
3
/min)
SLC 20 300 400
SLC 30 350 450
SLC 40 450 550
SLC 45, SLC 45R 550 750
SLC 70 750 900
Figure 4-3: Minimum and Maximum Exhaust Airflow Requirements for SLC Consoles